Drug-delivery device recalls
Recalls of insulin pumps and pens, infusion pumps, syringes, glucose monitors, inhalers, nebulizers and auto-injectors - 827 reports.
Class ITerminatedMar 25, 2020CME America BodyGuard Infusion Pump SystemInfusion Pump Systems may have a delivery inaccuracy of up to 13%, which may result in 1) faster than expected drug delivery when infusing at a very low rate (0.1 mL/h)...CME America, LLC · Z-1474-2020Class IITerminatedMar 18, 2020Monoject 3mL Syringe with Hypodermic Safety NeedleNon-sterile product was shipped to customers. Product package is labeled as both "STERILE" and "NON-STERILR" ; the product did not undergo sterilization process and is...Cardinal Health 200, LLC · Z-1453-2020Class ITerminatedMar 18, 2020BodyGuard Microset REF A120-003XYVAWhen using a specific tubing set with infusion pump system, may result in under deliver of fluids.CME America, LLC · Z-1442-2020Class IOngoingMar 11, 2020CareFusion Alaris Syringe Module1)Error 255-XX-XXX results in inability to edit settings 2)Delay options programming may result in no KVO rate/therapy interruption 3)Software errors results in no low...CareFusion 303, Inc. · Z-1361-2020Class IITerminatedFeb 19, 202010 cc Luer-Slip Loss of Resistance SyringeThere is the potential for various failures with the LOR (loss of resistance) syringes included in the kits resulting in dural puncture with some also requiring a blood...Arrow International Inc · Z-1205-2020Class IIOngoingFeb 19, 2020Prometra II Programmable 20mL Pump. Catalog No. 93827 The device is an implantable infusion pump. GTIN-14...A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1125-2020Class IIOngoingFeb 19, 2020Prometra Programmable 20mL Pump. Catalog No. 91827 The device is an implantable infusion pump. GTIN-14...A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1124-2020Class IIOngoingFeb 19, 2020US Clinical 20mL Programmable Pump. Catalog No. 01827 The device is an implantable infusion pump. GTIN-14...A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1123-2020Class IIOngoingFeb 19, 2020Prometra II 40mL Pump. Catalog No. 16827 The device is an implantable infusion pump. GTIN-14 00810335020242A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1122-2020Class IIOngoingFeb 19, 2020Prometra II 20mL Pump. Catalog No. 13827 The device is an implantable infusion pump. GTIN-14 00810335020228A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1121-2020Class IIOngoingFeb 19, 2020Prometra Programmable 20mL Pump. Catalog No. 11827 The device is an implantable infusion pump. GTIN-14...A pump alarm function anomaly in the pump firmware code may result in the pump not sending the expected error code notifications to the Programmer, or not emit an...Flowonix Medical Inc · Z-1120-2020Class ITerminatedFeb 19, 2020HUDSON RCI COMFORT FLO Humidification System With Remote Temperature PortThere is the potential for water to flood the column and enter the circuit under circumstances where an abnormal pressure differential is created between the water...Teleflex Medical Inc · Z-1115-2020Class ITerminatedFeb 19, 2020HUDSON RCI COMFORT FLO Humidification SystemThere is the potential for water to flood the column and enter the circuit under circumstances where an abnormal pressure differential is created between the water...Teleflex Medical Inc · Z-1114-2020Class ITerminatedFeb 19, 2020HUDSON RCI COMFORT FLO Corrugated Humidification System with Remote Temperature PortThere is the potential for water to flood the column and enter the circuit under circumstances where an abnormal pressure differential is created between the water...Teleflex Medical Inc · Z-1113-2020Class ITerminatedFeb 19, 2020HUDSON RCI COMFORT FLO Corrugated Humidification SystemThere is the potential for water to flood the column and enter the circuit under circumstances where an abnormal pressure differential is created between the water...Teleflex Medical Inc · Z-1112-2020Class IOngoingFeb 19, 2020Medtronic MiniMed 640G Insulin Infusion PumpThere have been reported incidents of a loose reservoir that can no longer be locked into the pump. The reservoir can become loose due to a broken or missing retainer...Medtronic Inc. · Z-0958-2020Class IOngoingFeb 19, 2020Medtronic MiniMed 620G Insulin Infusion PumpThere have been reported incidents of a loose reservoir that can no longer be locked into the pump. The reservoir can become loose due to a broken or missing retainer...Medtronic Inc. · Z-0957-2020Class IITerminatedFeb 12, 2020ACCU-CHEK AVIVA ASPAC STRIP 50CT- intended for Blood Glucose Monitoring System Catalog Number: 06453970020Inability to dose the test strips, may result in a temporary inability to get a result that could lead to a delay in treatment and/or therapy decisionsRoche Diabetes Care, Inc. · Z-0999-2020Class IITerminatedFeb 12, 2020Accu-Chek Aviva Plus Retail Strips 50 ct - intended for Blood Glucose Monitoring System Catalog Number...Inability to dose the test strips, may result in a temporary inability to get a result that could lead to a delay in treatment and/or therapy decisionsRoche Diabetes Care, Inc. · Z-0998-2020Class IITerminatedFeb 12, 2020Accu-Chek Aviva Plus Health Network Strips- intended for Blood Glucose Monitoring System Catalog Number...Inability to dose the test strips, may result in a temporary inability to get a result that could lead to a delay in treatment and/or therapy decisionsRoche Diabetes Care, Inc. · Z-0997-2020Class IITerminatedFeb 12, 2020Dexcom ReceiverIt has been reported that use of the mobile receiver with software version SW10617 rev 4.0.1.048 have reported: 1. the receiver becoming stuck on initialization screen...Dexcom Inc · Z-0929-2020Class IITerminatedFeb 5, 2020Bard Conquest 40 PTA Dilation CatheterThe catheter packaging incorrectly listed the balloon size as 8mm X 20mm instead of the intended size 8mm X 40mm. If undetected, the user will advance the longer than...Bard Peripheral Vascular Inc · Z-0917-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0752-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0751-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0750-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0749-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0748-2020Class IITerminatedJan 8, 2020Blood Glucose Monitoring SystemPotential power issues with the Accu-Chek¿ Guide Blood Glucose Monitoring System.Roche Diabetes Care, Inc. · Z-0747-2020Class ITerminatedDec 18, 2019Medfusion Syringe PumpThere is an anomaly in Medfusion 4000 Syringe Pump Firmware version 1.7.0 that could potentially result in loss of primary audible and visual battery alarm...Smiths Medical ASD Inc. · Z-0610-2020Class IIIOngoingDec 4, 2019Platelet Aggregation KitThrough an investigation, it has been determined that vials of Collagen packaged within the Collagen Reagent and Platelet Aggregation Kit may contain particulate matter...Helena Laboratories, Corp. · Z-0536-2020Class IITerminatedDec 4, 2019EVENCARE G3 Blood Glucose Test StripsIncomplete seal and premature expiration of individually packaged Blood Glucose Test Strips.Medline Industries Inc · Z-0513-2020Class IITerminatedNov 20, 2019Cadence Science Pressure Control Glass SyringeThe glass syringe used with Pressure Control Syringes may potentially break during use.Cadence Science, Inc. · Z-0365-2020Class IITerminatedNov 13, 2019Omnipod DASH Insulin Management SystemThere is a potential for a communication interruption following a bolus command that may result in inaccurate information presented in insulin on board (IOB), last bolus...Insulet Corporation · Z-0347-2020Class IIOngoingNov 13, 2019Petfine Auto InjectorThere is a possible assembly error on Autoject EI, lot number V14. This lot was packed into two products: AJ 1310, lot number V14 and AN 3310VET (branded as Petfine Auto...Owen Mumford USA, Inc. · Z-0264-2020Class ITerminatedNov 13, 2019Minimed Model 503 Remote TransmitterThere is a potential security vulnerability related to the use of the remote controller accessories with the insulin pumps.Medtronic Inc. · Z-0178-2020Class ITerminatedNov 13, 2019Minimed Model 500 Remote ControlThere is a potential security vulnerability related to the use of the remote controller accessories with the insulin pumps.Medtronic Inc. · Z-0177-2020Class IITerminatedNov 6, 2019Dario Blood Glucose Monitoring SystemThe Dario-Blood Glucose Tracker Android App versions 4.3.0-4.3.2 may experience duplicate logging of a blood glucose level reading.Labstyle Innovations · Z-0260-2020Class IITerminatedNov 6, 2019Eversense CGM SENSOREversense Sensors have prematurely stopped functioning due to inadequate hydration of the sensor s glucose-sensing surfaceSenseonics, Inc. · Z-0251-2020Class IITerminatedOct 30, 2019Plum 360 Infusion System With MedNet/ Smart Card Plug And Play ModuleA software malfunction of the infuser when used with a MedNet Custom Drug Library (CDL). When a new CDL is downloaded and installed on the infuser the infuser can become...ICU Medical Inc · Z-0171-2020Class IITerminatedOct 23, 2019Infusion Pump I.V. AdministrationPotential for fluid leakage out of air vents on inline filters on Plum and Sapphire micropore infusion sets.ICU Medical Inc · Z-0147-2020